Electrode

Small reference electrodes

Compatible with small analytical cells

Reference electrodes need to have an intrinsic redox potential that is stable. A large variety of small reference electrodes is available to cover all different electrolytes and applications.

In electrochemistry, the most basic equipment to be able to perform your experiment is a reference electrode. A reference electrode has a fixed electrochemical potential and is used to apply a potential difference to the electrode. Depending on your electrolyte and your system, you might want to prefer using chloride-based reference electrodes (Calomel, Ag/AgCl) or sulfate-based electrodes (Hg/HgSO4). Small reference electrodes are compatible with small analytical cells. Replacement kits are also available.

Aqueous media

 

Various electrodes are offered using either ceramics or porous glass as material for the junction.

 

 

Catalogue numberJunctionElectrolytePurpose
RE-1B reference electrode (Ag/AgCl – length: 78 mm, OD: 6 mm)A-012167IPPG3 M NaClSVC-2, SVC-3, VC-4, bulk electrolysis, RRDE-3A, flat cell
RE-1S reference electrode (Ag/AgCl – length: 52 mm, OD: 4.5 mm)A-012168IPPG3 M NaClSECM
RE-1BP reference electrode (Ag/AgCl – length: 90 mm, OD: 6 mm)A-013613Ceramics3 M NaClSVC-2, SVC-3, VC-4, bulk electrolysis, RRDE-3A, EQCM, flat cell
RE-1CP reference electrode (Ag/AgCl – length 92 mm, OD: 6 mm)A-013429CeramicsSaturated KClSVC-2, SVC-3, VC-4, bulk electrolysis, RRDE-3A, flat cell
Ag/AgCl ink, 2 mLA-011464surface resistance: 0.2 Ω/sq/25.4 µm
viscosity: 50,000 ±10,000 CP @21.1 °C
flash point: 82 °C
For micro CV cell, IDA measurement
RE-2BP calomel reference electrode (length: 92 mm, OD: 6 mm)A-013430CeramicsSaturated KClSVC-2, SVC-3, VC-4, bulk electrolysis,RRDE-3A, flat cell
RE-2CP reference electrode (Hg/Hg sulfate – length: 92 mm, OD: 6 mm)A-013431IPPGSaturated K2SO4SVC-2, SVC-3, VC-4, bulk electrolysis,
RDE/RRDE, flat cell
RE-61AP reference electrode (Hg/HgO – length: 92 mm, OD: 6 mm)A-013395Ceramics1 M NaOHor micro CV cell, IDA measurment

 

 

Non-aqueous media (Ag/Ag+)

 

Catalogue numberJunctionElectrolytePurpose
RE-7N non aqueous reference electrode (Ag/Ag+)A-013848IPPG*No electrolyte provided
Documentation about how to prepare the internal solution available here
CV
RE-7SN non aqueous reference electrode (Ag/Ag+)A-013849IPPG*SECM

 

* Ion Permable Porous Glass
** Acetonitrile
*** Tetra Butyl Ammonium Perchlorate

 

Options and spare parts

 

Catalog No.
Options
RE-PV preservative vial for reference electrode, 10 mLA-012108
Bridge tube Ø 9.0 mm (2 pieces)A-012177
Bridge tube Ø 9.0 mm (22 pieces)A-012307
Spare parts
Electrolyte solution (10 mL)A-012549
PTFE cap with Ag wire (for RE-7)A-012057
PTFE cap with Ag wire (for RE-7S)A-012058
Sample holder 6 mm diameter (for RE-7) (2 pieces)A-012176

 

Junction replacement kits

 

Replacement kitsCompatible
reference electrodes
Compatible
bridge tubes
Content
092-VYC3
A-012167
A-012178
A-012176
A-012306
A-012177
A-012307
10 glass frits (ф 2.8mm Coralpor™)
200 mm long heat shrink tube (ф 3.2 mm)
092-VYC4
Ø
EL-C-005
EL-C-017
EL-F-004B
EL-F-004
EL-A-017
EL-A-008
10 glass frits (ф 4 mm CoralPor™)
200mm long heat shink tube (ф 4.8 mm)
092-VYC5
A-012168
Ø
10 glass frits (ф 2.8 mm CoralPor™)
200 mm long heat shrink tube (ф 4.8 mm)

 