Electrode

Working electrodes

This is where it all happens

Working electrodes are of utter importance because this is where everything that interests the electrochemist will happen. A large offer of working electrodes are available with a very wide range of size and materials.

9 metals are available: Carbon, Pt, Au, Ag, Pd, Ni, Cu, Fe, BDD (Boron-doped diamond), as well as empty electrodes to host carbon paste that is also available.
Different sizes are available from 5 mm down 10 µm.

 

A polishing kit is also available.

 

 

Note the UME electrode dedicated to SECM are available here:

https://my.biologic.net/accessory/secm-ume-probes/

More details are given in the specifications section.

Specifications and ordering information

 

These working electrodes are all made of a PEEK isolation body.

 

OD /mmElectrode size /mmCatalog No.
CarbonStandard glassy carbon10 mm5 mmA-002417
6 mm3 mmA-002012
6 mm1.6 mmA-012297
Small glassy carbon3 mm1.6 mmA-012298
3 mm1 mmA-002412
Standard Pyrolytic graphiteBasal Plane6 mm3 mmA-002252
Edge Plane6 mm3 mmA-002253
Standard plastic formed6 mm3 mmA-002408
6 mm1 mmA-002409
Small Plastic formed carbon3 mm1 mmA-011854
PlatinumStandard Platinum10 mm5 mmA-002420
6 mm3 mmA-002422
6 mm1.6 mmA-002013
Small Platinum3 mm1.6 mmA-002313
GoldStandard Gold10 mm5 mmA-002418
6 mm3 mmA-002421
6 mm1.6 mmA-002014
Small Gold3 mm1.6 mmA-002314
SilverStandard Silver10 mm5 mmA-002416
6 mm3 mmA-002419
6 mm1.6 mmA-002011
Small Silver3 mm1.6 mmA-002315
PalladiumStandard Palladium6 mm1.6 mmA-002019
Small Palladium3 mm1.6 mmA-002319
NickelStandard Nickel6 mm1.5 mmA-002016
CopperStandard Copper6 mm1.6 mmA-002017
6 mm3 mmA-012584
IronStandard Iron6 mm1.5 mmA-002018
6 mm3 mmA-012585
Carbon pasteStandard Carbon paste, hole depth 4 mm6 mm3 mmA-002210
Small Carbon paste, hole depth 4 mm3 mm1.6 mmA-002223
Carbon paste oil base 1 gA-001010
Boron-doped diamondDoping level between 500 and 1000 ppm.
The electrode is 500 µm disk attached to a conductive rod in brass. It is polished with an Ra<10 nm.
7 mm3 mmM-BDD-3

 

Working electrodes maintenance

To refresh the surface of the electrode we recommend to polish the electrode before each measurement.

 

Catalog No.
PK-3 electrode polishing kit A-011975
Contents
0.05 µm polishing alumina (20 mL) A-001050
1 µm polishing diamond (10 mL) A-002054
Glass plate (1 piece) A-002249
Alumina polishing pad (10 pieces)
Diamond polishing pad (10 pieces)
Replacement items
Alumina polishing pad (20 pieces) A-001040
Diamond polishing pad (20 pieces) A-001041
Emery paper UF800 (20 pieces) A-012611
Coarse polishing pad (20 pieces) A-001042

 

Related topics

Le Lorem Ipsum est simplement du faux texte employé dans la composition et la mise en page avant impression. Le Lorem Ipsum est le faux texte standard de l'imprimerie depuis les années 1500.

Request a quote.

Our team is ready to help